The usual supplier evaluation collects six documents and verifies none of them: a quality system certificate as a JPEG, a water leak report with no revision on it, a CE statement with no regulation named. Every one can be genuine and still say nothing about the gloves in your container, because none is tied to the model, weight and lot you are buying.
This is the checklist we would hand a buyer auditing us, from the line side. Four of these checks cost nothing but an email, and they eliminate most of the field.
Verify the certificate instead of filing it
A quality system certificate is checkable, and most buyers never check it. Accredited management system certifications are listed in IAF CertSearch, the International Accreditation Forum’s global database, searchable by company name or certificate number, with bulk upload if you are screening several suppliers at once. Two things before you draw a conclusion: ISO itself issues no certificates and accredits no certification bodies, and the database holds accredited certificates only, with coverage that has never been complete. An entry is strong evidence; an absence is a question, not a verdict — confirm with the certification body named on the document.
Then read the scope line, where most supplier files quietly fail. ISO 13485 certifies a quality management system, not a product, and the certificate states an issuer, a scope and a validity window. A scope covering trading and sales but not production tells you the holder does not make the goods. A certificate held by a group company rather than the site that will run your order tells you the audit never visited your line. Ask three things in writing: which legal entity holds it, which site and activities the scope covers, and who the issuing body is. Our Taishan glove plant in Dajiang, Guangdong holds its own ISO 13485 certificate; ask for a copy with the quotation and check its issuer and scope against the database — we do not publish certificate numbers on web pages.
One phrasing to treat as a red flag either way: a supplier describing the products as holding the ISO 13485 certification. The standard certifies the system, not the goods, and a supplier who writes it the other way round is either careless with regulatory language or counting on you being careless.
The two CE meanings, and the question that separates them
This check tells you most reliably whether the person on the other side of the email understands their own product.
Examination gloves usually sit under two European regimes at once. As a medical device, non-sterile examination gloves are Class I under Regulation (EU) 2017/745 — a self-declared route, where the EU Declaration of Conformity is issued by the legal manufacturer and the CE mark carries no notified body number. As personal protective equipment against biological or chemical agents, the same gloves are typically Category III under Regulation (EU) 2016/425, which does involve a notified body, and there the CE mark carries a four-digit notified body number.
So when a supplier offers “our CE certificate”, ask which regulation it is issued under. A notified body certificate for the medical device route on a Class I glove is not the document they think it is. Nothing at all for the PPE route, when your customers buy on PPE grounds, is a gap you have found before your customer did. Our gloves are CE marked under the applicable EU regulations and the EU Declaration of Conformity is provided with the quotation for the model and market you are buying.
The American side has its own confusion worth pre-empting: registration is not approval. Under 21 CFR 807.39, establishment registration and device listing do not denote FDA approval of the establishment or its products, and FDA publishes a database you can search yourself rather than taking a screenshot on trust. Examination gloves are Class I reserved devices requiring premarket notification, a different thing again from registration. We provide the registration and device listing information for the US market with the quotation.
What a sample actually proves, and what it does not
| Check | What it tells you | What it does not tell you |
|---|---|---|
| Water leak test to ASTM D5151 (glove filled with 1000 ml of water) | Freedom from holes that leak under the test conditions; also recognised under EN 455-1 | The standard does not establish the smallest detectable hole, so it is not a general barrier-integrity claim |
| EN 455-2 physical properties | Median force at break and dimensions on the tested lot | Nothing about the next lot, unless the method and limits are in your purchase order |
| EN 455-3 biological evaluation | Biocompatibility, powder and protein positions for the tested product | Nothing about a model with a different compound or surface treatment |
| EN 455-4 shelf life | The basis for the expiry date claimed | Whether your storage conditions match those the data came from |
| Weight per glove | How the quote was built — the price is built on gram weight | The thickness your incoming inspection measures in mil; ask for both |
Two material-specific traps live in that table. First, EN 455-2’s force at break is banded by material: ≥6.0 N for rubber examination gloves such as nitrile, ≥9.0 N for surgical gloves, ≥3.6 N for thermoplastic examination gloves such as vinyl, as the median of thirteen gloves. A supplier applying 6 N to a vinyl glove has copied a nitrile line, and an amendment revised that table to resolve misreadings — ask which revision the report is written against. Second, a report borrowed from a sister model or an older revision is the most common document defect in this trade, invisible unless you check that the model code and revision match the item on your purchase order.
Our published 3.5 g specification is force at break ≥6 N, elongation 400%, length ≥240 mm and a weight tolerance of ±0.3 g on the M size; ask any supplier for the report on your lot rather than a range-wide sheet.
One historical item still worth asking, because old specifications circulate: powdered patient examination gloves and powdered surgeon’s gloves have been banned in the United States since 18 January 2017, under a final rule that applies regardless of glove material. A supplier offering a powdered option for the US market in 2026 is working from a pre-2017 sheet.
Out-of-line inspection and the AQL figure that must name a market
Sampling is the uncontroversial half: pull against ISO 2859-1, general inspection level II, lot defined as the production batch.
The acceptance figure is not, and getting it backwards is the clearest sign of a supplier reading someone else’s standard. For the US market the applicable figure for examination gloves is AQL 2.5 under 21 CFR 800.20; the EU applies AQL 1.5 under EN 455-1. Name the destination market in every enquiry and check that each quotation states the matching figure. Our own out-of-line inspection runs at the EN 455-1 figure of AQL 1.5; agree in writing whether your nominated inspection company or your own staff will inspect on site.
What to ask to see on site, in the order it tells you most:
- The batch record for a lot already shipped, traced from compound to packed case.
- The out-of-line inspection log for that lot, with defect classes named rather than a pass stamp.
- The water leak station in use, and the sample size drawn against the lot size.
- The certificate of analysis for the compound, and how a change of compound supplier is recorded.
- The box and case print approval for a private label order, with the artwork sign-off on file.
A line that can produce all five for a lot you pick at random will produce them for yours. A line that produces beautiful documents only for the lot they selected is telling you something.
Case, cube and the commercial terms
| Commercial term | What to fix in the purchase order |
|---|---|
| Pack hierarchy | Glove → box → case → pallet. Our packing is 100 pieces per box and 10 boxes per case; confirm the piece count per box for every size you order |
| Count reconciliation | Reconcile by piece, not by case: XL is commonly packed at a lower count per box than M at the same boxes per case, the most common invoice dispute in gloves |
| Loadability | As planning figures only: 20ft roughly 26–28 m³, 40ft 55–58 m³, 40HQ 65–68 m³. Gloves cube out long before they weigh out |
| Pallet configuration | Pallet type, cases per tier, tiers per pallet, pallet-in or floor-loaded, and whether heat-treated pallets are needed at your port |
| Incoterm and port of loading | State both. EXW, FOB Shenzhen and DDP are three different prices; compare like with like and check your own duty line before setting a landed figure against a DDP quote |
| HS line | Medical gloves of vulcanised rubber sit at 4015.12. Confirm the national subheading against the tariff of the country of import before you compare our number with a delivered quote |
| Price basis | Indicative USD per case against the current NBR index, with a stated validity window rather than an open-ended price. An open-ended price in gloves usually means there is room in the gram weight |
| MOQ, lead time, payment | Our MOQ is flexible. Tell us the quantity you need and we will quote accordingly. Lead time is confirmed with each quotation. Payment terms are confirmed with each quotation. On private label, ask each supplier for its box print minimum; it usually sets the floor |
Samples: two different conversations
A stock sample settles feel, donning, colour and box quality, and it is what gets you into a comparison. A development sample answers “can you run my specification” — compound, colour match, weight tolerance, print — and carries a trial run and an approval step. Ask for a development sample when a stock sample would do and you lose weeks; accept a stock sample as proof of a custom specification and you find out at the first run. Name the question you are asking when you request a sample.
Change control, traceability and responsibility
The third order is where this trade goes wrong, not the first. Ask every supplier for a written change notification policy covering a change of compound supplier, pigment, surface treatment, box print or production site. A change of compound supplier is the one most often treated as internal — it is not, because it can move both the physical properties and the biocompatibility file your own customer holds.
Ask for the lot code on the box and the case so a complaint traces to one batch, and for the lot-code key with the first shipment. Ask for specification changes to be notified in writing; if your quality system needs an approval gate before a changed product ships, raise it at the purchase order stage so it sits in the terms.
Three fields belong on your supplier file before the first order, whoever you buy from: the legal manufacturer named on the box, the EU authorised representative or responsible person for Europe, and the US agent of record. A buyer who cannot name all three has no route of recourse that does not run through their salesperson. Ask each supplier to confirm all three for your destination market in writing.
When a full audit is not worth it
If your first order is a single mixed case pack for a trade customer to evaluate, a third-party audit costs more than the order and delays it by weeks. Get the stock sample, check the certificate in the accreditation database, ask the two CE questions and the AQL-by-market question, and keep the audit for the order where volume justifies it. We would rather you spent that money on the second order than on a report about the first.
Start from the MXGUARD® nitrile exam gloves page, or the HM-1101 nitrile gloves 3.5 g item whose published specification is quoted above; the full nitrile gloves manufacturer range sits one level up. For the acceptance figure in detail, see AQL for examination gloves explained; for the certificate landscape, glove certifications: FDA, CE and ISO 13485; and once the supplier is settled, importing disposable gloves from China covers the shipping and customs side that this article deliberately leaves out.
FAQ
How do I verify a nitrile glove manufacturer's ISO 13485 certificate?
Search IAF CertSearch by company name or certificate number, then read the scope line to confirm it covers production at the site that will run your order rather than sales or trading by a group company; because only accredited certificates are listed and coverage is incomplete, an absence is a question rather than a verdict, so confirm with the issuing body named on the document.
What does the water leak test actually prove?
Under ASTM D5151 the glove is filled with 1000 ml of water and inspected for leakage, demonstrating freedom from holes that leak under those conditions; the method is also recognised under EN 455-1. The standard does not establish the smallest detectable hole, so treat the result as a hole check on the sampled lot, not a general barrier claim, and check that the report names your model and lot.
Which AQL should appear on my purchase order?
It depends on the destination market, which is where most quotations go wrong: the US figure for examination gloves is AQL 2.5 under 21 CFR 800.20 while the EU applies AQL 1.5 under EN 455-1. Name the market in every enquiry and check that each quotation states the matching figure; our own out-of-line inspection runs at the EN 455-1 figure of AQL 1.5, and whether your nominated inspection company or your own staff inspect on site is worth agreeing in writing.
How is the minimum order quantity set, and what about lead time and payment?
Our MOQ is flexible. Tell us the quantity you need and we will quote accordingly. Lead time is confirmed with each quotation. Payment terms are confirmed with each quotation. On private label, ask each supplier for its box print minimum, because that, not the gloves, usually sets the practical floor.